福建Mitutoyo Ultra-high Accuracy Digimatic Micrometer 293-100-20
•The flagship model, featuring unparalleled high accuracy and resolution.
•Maximum Permissible Error (JMPE) of±0.5 μm is achieved with our innovative
0.1 μm resolution ABS (absolute) rotary sensor and screw machining technology
highly rigid frame and high-performance constant-force mechanism allow stable measurements.
•Body heat transferred to the instrument is reduced by a (removable) heat shield, minimizing the error caused by thermal expansion of the frame when performing handheld measurements.
SPECIFICATIONS
Metric
Inch/ Metric
Code
No.
293-100-20
293-130-20
Measuring range
0 – 25 mm
0 – 1 in
Resolution
0.0001 mm/ 0.0005 mm
(switchable)
0.000005 in / 0.00002 in
0.0001
mm/ 0.0005 mm
(switchable)
Maximum permissible
error JMPE
±0.5 μm
±0.00002 in
Flatness
0.3 μm
0.000012 in
Parallelism
0.6 μm
0.000024 in
Measuring surface
ø3.2 mm
Measuring force
7 to 9 N
Position detection method
Electromagnetic induction type ABS rotary sensor
Mass
405 g
(445 g with heat shield attached)
Power
source
Lithium battery (CR2032) ×1
Battery life
Approx. two years when used under normal conditions
Functions
Preset (ABS measurement system):
The measurement origin can be preset to any value within the display range for convenience in measuring.
Zero-setting (INC measurement system):
The display can be zeroed at any position of the spindle, making comparison measurement easier. Returning to the absolute-measurement mode is easily accomplished.
Hold:
The function that holds the display of value is useful when it is difficult to see the measured value at the measurement point. When the function is cancelled, the previous zero-set point or a measured value with reference to the origin is displayed.
Resolution switching:
The resolution of the display can be switched. If 0.1 μm measurement is not required, the resolution can be switched to 0.5 μm.
Function lock:
Functions such as preset or zero-set can be locked to avoid inadvertently changing the origin position.
On/ off:
The power can be turned off after measurement is complete. Even after the power is turned off, the origin or last zero-set position remains in the memory.
Auto power off:
Even if the power is left on, the power turns off automatically if the micrometer is not used within a 20-minute period.
Measurement data output:
Measurement data can be output, allowing easy incorporation of this instrument into a statistical process control or measurement system.
Error alarm:
In the unlikely event of a display overflow or calculation error, an error message is displayed and measurement stops. Measurement cannot continue until the error is corrected.
Also, if the battery voltage drops below a certain point, the battery indicator will turn on before measurement becomes impossible, warning the user that the battery needs to be replaced.
相关资讯
联系我们
免费热线:18866860691 QQ: